제목 The Design of Cardiopulmonary Exercise Test Protocol using Aquatic Treadmill
소속 Sanggye Paik Hospital, Inje University College of Medicine, Department of Rehabilitation Medicine1, Haeundae Paik Hospital, Inje University College of Medicine, Department of Rehabilitation Medicine2, Wonkwang University College of Medicine, Department of Biomedical Engineering3
저자 Chul-Kim1†, Hee-Eun Choi 2*, Jin-seok Lee 3, Hwan-Kwon Do 2, Cheol-won On 2
Introduction> Cardiac rehabilitation (CR) is an integral part of the continuum of care for patients with cardiovascular disease. The core components of CR include patient evaluation. A cardiopulmonary exercise (CPX) test is a key component of the initial assessment made before a patient begins an exercise program. The test is performed as the metabolic equivalent (MET) is constantly increased at regular intervals according to the protocol. Aquatic treadmill (AT) employs underwater treadmill that combines the benefits of fluid resistance and the body weight supporting effect of buoyancy. AT can be used to evaluate exercise capacity in patients with difficulty in standing and walking as an alternative to land treadmill based CPX test. However, there is currently no CPX test protocol using AT, and it is necessary to develop a standardized aquatic treadmill CPX test protocol. Therefore, this pilot study was conducted to design a CPX test protocol that can bring about a constant change in MET value using AT.
Method> Nineteen male and one female subjects were enrolled in this study. Their mean age was 31.6 ± 6.9 years. The depth of the water pool was set up between xiphoid process and umbilicus. The room temperature was maintained at 25oC−26oC, while the water temperature was maintained at 28oC−29oC. The AT test comprised 12 stage at different velocities, with 2-minute duration per stage. The speed of the treadmill started at 0.7km/h in stage 1 and increased by 0.7 or 0.6 km/h in each stage. After the end of the test, individuals rested while standing for additional 2 minutes at cool down phase. A respiratory gas analyzer (Quark-CPET, COSMED, Rome, Italy), automatic blood pressure (BP) analyzer (Tango M2, SunTech Medical, USA), pulse oximeter (Care vision HP-110) and an AT (Aquatrac-2000, Naramed, Gwangju, Korea) were used. Moreover, electrocardiograms (ECGs) were monitored using by 10 carbon electrodes made of graphite and cables made of copper applicable in water with 12 channel ECGs for real-time CPX test (CASE, GE healthcare, USA). At each stage, oxygen consumption (VO2), METs, heart rate (HR), BP, respiratory exchange ratio (RER), minute ventilation (VE), VE/VCO2 and rate of perceived exertion (RPE) were measured.
Result> For analysis, all recorded values of each stage were averaged. At stage 2 (1.4km/h), VO2 value corresponded to approximately 2 METs (VO2, 6.94 ± 1.05) in all subjects. 3.35 METs (VO2, 10.57 ± 1.09) were measured at stage 5 (3.3km/h). And 4.16 METs (VO2, 13.06 ± 1.46), 4.99 METs (VO2, 15.51 ± 1.54) were measured at stage 6 (4km/h) and 7 (4.6km/h), respectively. The parameters of AT CPX test for each stage are shown in Table 2. As the exercise intensity increased at each stage, HR and RPE was incrementally increased.
Conclusion> It was demonstrated that AT walking can lead to high METs at lower speed than land treadmill walking. This means that AT walking can load higher exercise intensity than land treadmill at same speed
File.1: Table 1.jpg
Table 1. General characteristics of subjects
File.2: Table 2.jpg
Table 2. The parameters of aquatic treadmill cardiopulmonary exercise test for each stage